Schumacher 50 Amp EV Charger Review
The Schumacher SEV1600P650 Level 2 EV Charger delivers 50 Amps of 240V charging, offering up to 9X faster charging than standard models. Compatible with NEMA 6-50 plug or hardwiring, it features Bluetooth/WiFi connectivity for remote monitoring and control. Ideal for indoor or outdoor installation, it ensures efficient, reliable performance.
The Schumacher 50 Amp EV Charger offers fast and reliable charging for electric vehicles. It can charge up to nine times faster than a standard wall outlet, making it an efficient option for home use. The current can be adjusted during installation, ranging from 16A to 40A, allowing you to customize the charging speed to suit your home’s power system.
This charger is built to last. It comes with a weather-resistant enclosure that protects it from rain and snow, making it suitable for outdoor installation in harsh conditions. The 25-foot charging cable provides enough length to reach different areas of your garage or driveway, offering flexibility for multiple vehicles.
One of its key features is smart home compatibility. You can monitor and control the charger using the SchuPower app, providing remote access to your vehicle’s charging status. This feature is particularly useful for those who want to manage their charging process from the comfort of their home.
The charger is easy to install, with clear instructions that make the process straightforward. Its durable construction and long cable ensure long-term reliability. Additionally, the charger’s design is compact, ensuring it doesn’t take up too much space in your garage. The pulsing LED lights add a modern touch.
However, the app’s interface feels basic, and the charger only includes a J1772 connector, which means you’ll need a separate adapter for Tesla vehicles. Another limitation is the lack of integration with voice assistants like Google Home, Apple Home, or Alexa, which could improve its smart home capabilities.
Plug-in Schumacher 50 Amp EV Charger Outlet Installation
The Schumacher 50 Amp EV Charger supports outlet installations for flexible and efficient EV charging. Its adjustable amperage settings allow compatibility with various electrical circuits while ensuring safe and reliable operation. Each amperage level aligns with specific outlet and circuit breaker requirements. There are two installation options for the plug-in Schumacher 50 Amp EV Charger: a NEMA 14-50R outlet or a NEMA 6-50 outlet. The choice depends on the type of plug your charger model uses.
The Schumacher 50 Amp Plug-in EV Charger supports 20A, 30A, 40A, and 50A amperage. For 60A, 70A, and 80A, hardwiring is required.
Schumacher 50 Amp EV Charger NEMA 14-50 Installation Guide
The figure below shows the wiring setup for installing a Schumacher 50 Amp EV Charger with a NEMA 14-50R outlet. It requires a 50-amp double-pole breaker, a main breaker, neutral, and ground busbars in a 120V/240V panel. Wiring uses 6 AWG 90°C copper wire in a ¾”–1¼” conduit and includes a ground rod for grounding. Labeled components are L1 (Hot 1), L2 (Hot 2), Neutral, and Ground. Use NEC-compliant NEMA 14-50 outlets that handle 40A continuous current on a 50A breaker.
Compatible NEMA 14-50 Outlets
Use NEC-compliant NEMA 14-50 outlets for reliable performance. These outlets handle 40A continuous current on a 50A circuit breaker and support 6 AWG wiring for safe and efficient charging.
Schumacher 50 Amp EV Charger NEMA 6-50 Installation Guide
Installing the Schumacher 50 Amp EV Charger with a NEMA 6-50 outlet differs from the NEMA 14-50 outlet installation. The NEMA 6-50R outlet features two parallel hot prongs, with the larger prong positioned on the right, and a horseshoe-shaped ground prong.
For proper installation, configure the charger to 40 amps, connect the outlet to a dedicated 50-amp circuit breaker, and use a 6-gauge wire for the connection. The wiring should be enclosed in a conduit with an inner diameter ranging from 3/4″ to 1¼”.
Below, a detailed diagram illustrates how to wire the NEMA 6-50R outlet for the Schumacher 50 Amp EV Charger, with close-up views of the outlet’s terminal connections and the full branch circuit from the breaker panel to the outlet.
Recommended NEMA 6-50 Outlets for Optimal Performance
For optimal performance, choose the high-quality NEMA 6-50 outlets listed below. These outlets are NEC-compliant, capable of handling 40A continuous current on a 50A circuit breaker, and designed for 6 AWG wiring. This ensures safe and efficient charging, preventing overheating and ensuring reliable operation.
Schumacher 50 Amp EV Charger Compatible Outlet Covers
Outlet covers were installed during our Schumacher 50 Amp EV Charger setup. They protect against live electrical components, prevent tampering, enhance the installation’s look, save energy by sealing outlets, and display overload indicators. The covers also fit the plug and cable during use.
Schumacher 50 Amp EV Charger Hardwired Installation
The Schumacher 50 Amp EV Charger supports hardwired installations with adjustable amperage settings for tailored charging performance. Each amperage level corresponds to a specific wiring configuration and circuit breaker rating, ensuring safety and compatibility with various electrical setups.
For a 50A setting, use a 70A circuit breaker. For 48A, use a 60A breaker. For 40A, use a 50A breaker. For 32A, use a 40A breaker. For 24A, use a 30A breaker. For 16A, use a 20A breaker. These configurations ensure optimal operation and adherence to electrical safety standards, making the Schumacher charger a versatile choice for EV owners.
Schumacher EV Charger 50A Hardwire Wiring Diagram (70A Circuit Breaker)
The diagram for the Schumacher EV Charger 50A hardwired installation shows you will need 4 AWG wires for L1 and L2, and 4-6 AWG for the ground (G). A 70A circuit breaker ensures safety and supports a maximum output of 12 kW. The recommended conduit size is 1 to 1 1/4 inches. The Schumacher EV charger hardwired installation wiring diagram below also shows the DIP switch settings for the Schumacher EV charger, matching the 70A dedicated circuit breaker rating and the 50A amperage requirement.
Schumacher EV Charger 48A Hardwire Wiring Diagram (60A Circuit Breaker)
The diagram for the Schumacher EV Charger 48A hardwired installation shows you will need 4-6 AWG wires for L1 and L2, and 4-8 AWG for the ground (G). A 60A circuit breaker ensures safe operation and delivers a maximum output of 11.56 kW. The recommended conduit size is between 1 and 1 1/4 inches. The Schumacher EV charger hardwired installation wiring diagram below also illustrates the DIP switch settings of the Schumacher EV charger, corresponding to the 60A circuit breaker rating and the 48A amperage requirement.
Schumacher EV Charger 40A Hardwire Wiring Diagram (50A Circuit Breaker)
The diagram for the Schumacher EV Charger 40A hardwired installation shows you will need 6-8 AWG wires for L1 and L2, and 6-10 AWG for the ground (G). A 50A circuit breaker ensures safety and supports up to 9.6 kW of charging power. The recommended conduit size is 3/4 to 1 inch. The Schumacher EV charger hardwired installation wiring diagram below shows the DIP switch settings for the Schumacher EV charger, configured to match the 50A dedicated circuit breaker and 40A amperage needs.
Schumacher EV Charger 32A Hardwire Wiring Diagram (40A Circuit Breaker)
The diagram for the Schumacher EV Charger 32A hardwired installation shows you will need 8 AWG wires for L1 and L2, and 8-10 AWG for the ground (G). A 40A circuit breaker ensures safety and supports up to 7.68 kW of output. The recommended conduit size is 3/4 to 1 inch. The Schumacher EV charger hardwired installation wiring diagram below also presents the DIP switch settings for the Schumacher EV charger, adjusted to fit the 40A circuit breaker rating and 32A amperage requirement.
Schumacher EV Charger 24A Hardwire Wiring Diagram (30A Circuit Breaker)
The diagram for the Schumacher EV Charger 24A hardwired installation shows you will need 8 AWG wires for L1 and L2, and 8-10 AWG for the ground (G). A 30A circuit breaker ensures safety and supports up to 5.76 kW of output. The recommended conduit size is 1/2 to 1 inch. The Schumacher EV charger hardwired installation wiring diagram below also highlights the DIP switch settings of the Schumacher EV charger, set to correspond with the 30A dedicated circuit breaker and the 24A amperage.
Schumacher EV Charger 16A Hardwire Wiring Diagram (20A Circuit Breaker)
The diagram for the Schumacher EV Charger 16A hardwired installation shows you will need 8 AWG wires for L1 and L2, and 8-10 AWG for the ground (G). A 20A circuit breaker ensures safety and supports up to 3.84 kW of output. The recommended conduit size is 1/2 to 1 inch. The Schumacher EV charger hardwired installation wiring diagram below also shows how the DIP switch settings of the Schumacher EV charger align with the 20A circuit breaker rating and the 16A amperage requirement.
There are no reviews yet.